skip to main content

Riley Surface World uses cookies to give you the best experience on our website. If you continue we assume that you consent to receive cookies on our website. Read More

X
Machines & equipment for sale

Balco Engineering Ltd Manual Electropolish Line

Direct From Site Clearance

Price [?]
Please call on +44 (0) 1922 45 8000
Part of a Direct Site Clearance
Tecomet Medical
Condition
From a working environment, Seen working by RSW, Good Condition
Location
Sheffield, UK
Stock No
TEC300
Manufacturer
Balco Engineering Ltd
Model
Manual Electropolish
Year of Manufacture
2013
Serial
MS-0055
Condition
From a working environment, Seen working by RSW, Good Condition
Work Envelope (WxDxH mm) [?]
500 x 200/320/360/390 x 500
Process Stages
6
Other Info
Wall mounted control cabinet containing
Location
Sheffield, UK
External Dimensions (WxDxH mm) [?]
700 x 3140 x 2180mm
Delivery
Your delivery options

Description

Balco Engineering Ltd. Manual Electropolish Line

General Description

The plant comprises a series of tanks in an enclosed extracted canopy as detailed on the process schedule attached.

The equipment is arranged in a straight line with the work is carried from tank to tank manually by the operator.
Approximate plant dimensions 3140mm long x 700mm wide x 2180mm high to top of canopy.

Plus, ancillary equipment
• Rectifier & Pump 500mm long x 700mm wide.
• Wall Mounted Control Panel.

The line is fully consoled in polypropylene sheet and the tanks are located inside an integral PP bund with support stand to working height from factory floor level.

Specification of equipment

Tank No. 1 Process Electropolish

  • Temperature: 60°c
  • 1 Off Single compartment tank of internal size 360mm x 500mm x 500mm deep, complete with top flange.
  • The body of the tank is manufactured from polypropylene material.

Tank is supplied with:

  • Fume Extraction Canopy.
  • Lift off Tank Lid.
  • 1 Set Electric Heating Equipment complete with protection and control.
  • 1 Set Process Temperature Control.
  • 1 Set Solution Circulation Pump complete with suction and delivery pipework.
  • 1 Off Anode Bar
  • 2 Off Cathode Bars fitted with stainless steel cathode plates.
  • 1 Off Balco Rectifier 100 amps X 15 VDC

Tank No. 2 Process Rinse 1

  • Temperature: AMB
  • 1 Off Double compartment tank of internal size 390mm x 500mm x 500mm deep, complete with top flange.
  • Central division plate to form two 190mm wide compartments.
  • The body of the tank is manufactured from polypropylene material.

Tank is supplied with:

  • Fume Extraction Canopy.
  • Lift off Tank Lid.
  • 1 Off Water Inlet.
  • 1 Off Rear Overflow to drain.

Tank No. 3 Process Rinse 2

  • Temperature: AMB
  • 1 Off Single compartment tank of internal size 360mm x 500mm x 500mm deep, complete with top flange.
  • The body of the tank is manufactured from polypropylene material.

Tank is supplied with:

  • Fume Extraction Canopy.
  • Lift off Tank Lid.
  • 1 Off Bottom Water Outlet.
  • 1 Off Wash Off Gun.

Tank No. 4 Process Nitric Acid

  • Temperature: AMB
  • 1 Off Single compartment tank of internal size 200mm x 500mm x 500mm deep, complete with top flange.
  • The body of the tank is manufactured from polypropylene material.

Tank is supplied with:

  • Fume Extraction Canopy.
  • Lift off Tank Lid.

Tank No. 5 Process Rinse 3

  • Temperature: AMB
  • 1 Off Double compartment tank of internal size 390mm x 500mm x 500mm deep, complete with top flange.
  • Central division plate to form two 190mm wide compartments.
  • The body of the tank is manufactured from polypropylene material.

Tank is supplied with:

  • Fume Extraction Canopy.
  • Lift off Tank Lid.
  • 1 Off Water Inlet.
  • 1 Off Rear Overflow to drain.

Tank No. 6 Process Hot Rinse

  • Temperature: 60oc
  • 1 Off Single compartment tank of internal size 360mm x 500mm x 500mm deep, complete with top flange.
  • The body of the tank is manufactured from polypropylene material.

Tank is supplied with:

  • Fume Extraction Canopy.
  • Lift off Tank Lid.
  • 1 Set Electric Heating Equipment complete with protection and control.
  • 1 Set Process Temperature Control.
  • 1 Off Work Bar

Control Console


Wall mounted control cabinet containing two off electronic temperature controllers. Complete with contactors, circuit breakers and rail mounted terminal blocks.

Electrical Wiring

All electrical wiring between the central control console and field electrical items is installed in corrosion resistant PVC or galvanised-steel cable tray suitably supported.

Mechanical Services

One set mechanical services serving the previously described plant complete with all necessary supports and brackets.

Note if some pipework cannot be chemically cleaned and decontaminated to the standard necessary it will not be shipped and will need replacement on reinstallation.

 

pdf icon Print / Download Balco Engineering Ltd Manual Electropolish Line Datasheet

Additional files

Process Schedule

Photographs taken prior refurbishment. Our refurbishment service is not available on all machines.